9 research outputs found

    NUMERICAL PREDICTION OF THE COMPONENT-RATIO-DEPENDENT COMPRESSIVE STRENGTH OF BONE CEMENT

    Get PDF
    Changes in the compression strength of the PMMA bone cement with a variable powder/liquid component mix ratio were investigated. The strength test data served to develop basic mathematical models and an artificial neural network was employed for strength predictions. The empirical and numerical results were compared to determine modelling errors and assess the effectiveness of the proposed methods and models. The advantages and disadvantages of mathematical modelling are discussed

    DIAGNOSTIC FACTORS FOR OPENED AND CLOSED KINEMATIC CHAIN OF VIBROARTHROGRAPHY SIGNALS

    Get PDF
    The paper presents results of preliminary research of vibroarthrography signals recorded from one healthy volunteer. The tests were carried out for the open and closed kinematic chain in the range of motion 90° - 0° - 90°. Analysis included initial signal filtration using the EMD algorithm. The aim was to investigate the occurrence of differences in the values of selected energy and statistical parameters for the cases studied. &nbsp

    COMPARISON OF SELECTED CLASSIFICATION METHODS BASED ON MACHINE LEARNING AS A DIAGNOSTIC TOOL FOR KNEE JOINT CARTILAGE DAMAGE BASED ON GENERATED VIBROACOUSTIC PROCESSES

    Get PDF
    Osteoarthritis is one of the most common cause of disability among elderly. It can affect every joint in human body, however, it is most prevalent in hip, knee, and hand joints. Early diagnosis of cartilage lesions is essential for fast and accurate treatment, which can prolong joint function. Available diagnostic methods include conventional X-ray, ultrasound and magnetic resonance imaging. However, those diagnostic modalities are not suitable for screening purposes. Vibroarthrography is proposed in literature as a screening method for cartilage lesions. However, exact method of signal acquisition as well as classification method is still not well established in literature. In this study, 84 patients were assessed, of whom 40 were in the control group and 44 in the study group. Cartilage status in the study group was evaluated during surgical treatment. Multilayer perceptron - MLP, radial basis function - RBF, support vector method - SVM and naive classifier – NBC were introduced in this study as classification protocols. Highest accuracy (0.893) was found when MLP was introduced, also RBF classification showed high sensitivity (0.822) and specificity (0.821). On the other hand, NBC showed lowest diagnostic accuracy reaching 0.702. In conclusion vibroarthrography presents a promising diagnostic modality for cartilage evaluation in clinical setting with the use of MLP and RBF classification methods

    APPLICATION OF ACOUSTIC SIGNAL PROCESSING METHODS IN DETECTING DIFFERENCES BETWEEN OPEN AND CLOSED KINEMATIC CHAIN MOVEMENT FOR THE KNEE JOINT

    Get PDF
    The paper presents results of preliminary research of analysis of signals recorded for open and closed kinematic chain in one volunteer with chon-dromalacia in both knees. The preliminary research was conducted in order to establish the accuracy of the proposed method and will be used for for-mulating further research areas. The aim of the paper is to show how FFT, recurrence plots and recurrence quantification analysis (RQA) can help in bioacoustic signals analysis

    Application of an Artificial Neural Network in the Modelling of Heat Curing Effects on the Strength of Adhesive Joints at Elevated Temperature with Imprecise Adhesive Mix Ratios

    No full text
    This paper is a discussion of the results of tests intended to (i) estimate the effects of component mix ratios and heat curing of an adhesive joint on the tensile strength, and (ii) to determine the adhesive component mix ratio for which heat curing is insignificant to the strength of adhesive butt joints. Experimental tests were carried out at ambient temperature and elevated temperature during which adhesive butt joints were loaded with a tensile force until failure. The variables were the mix ratio of epoxy adhesive components and the application of heat holding at the adhesive curing stage. An LSTM (long short-time memory) forecast was used to determine the point corresponding to the mix ratio of adhesive components at which heat holding of the adhesive joint no longer has a positive and significant importance to the final tensile strength of the joint

    Experimental Verification of Standard Recommendations for Estimating the Load-carrying Capacity of Undercut Anchors in Rock Material

    No full text
    The recommendations put forward in the International Standards for anchorage in concrete concerning the assessment of the load-carrying capacity of anchors (the pull-out force) embedded in natural rock material were verified. Regarding the predicted extent of surface failure we have shown, in earlier studies, substantial discrepancies between the strength test results for anchorages in the rock mass and the established standard recommendations for anchorages in concrete. As regards the industrial practice and the goals of the reported project, simplified calculation procedures that will facilitate the selection of optimal configurations for the layout of anchor holes, while being computationally effective and applicable under the industry-specific conditions are sought

    Numerical prediction of component-ratio-dependent compressive strength of bone cement

    No full text
    Changes in the compression strength of the PMMA bone cement with a variable powder/liquid component mix ratio were investigated. The strength test data served to develop basic mathematical models and an artificial neural network was employed for strength predictions. The empirical and numerical results were compared to determine modelling errors and assess the effectiveness of the proposed methods and models. The advantages and disadvantages of mathematical modelling are discussed

    Diagnostics of Articular Cartilage Damage Based on Generated Acoustic Signals Using ANN—Part I: Femoral-Tibial Joint

    No full text
    Osteoarthritis (OA) is a chronic, progressive disease which has over 300 million cases each year. Some of the main symptoms of OA are pain, restriction of joint motion and stiffness of the joint. Early diagnosis and treatment can prolong painless joint function. Vibroarthrography (VAG) is a cheap, reproducible, non-invasive and easy-to-use tool which can be implemented in the diagnostic route. The aim of this study was to establish diagnostic accuracy and to identify the most accurate signal processing method for the detection of OA in knee joints. In this study, we have enrolled a total of 67 patients, 34 in a study group and 33 in a control group. All patients in the study group were referred for surgical treatment due to intraarticular lesions, and the control group consisted of healthy individuals without knee symptoms. Cartilage status was assessed during surgery according to the International Cartilage Repair Society (ICRS) and vibroarthrography was performed one day prior to surgery in the study group. Vibroarthrography was performed in an open and closed kinematic chain for the involved knees in the study and control group. Signals were acquired by two sensors placed on the medial and lateral joint line. Using the neighbourhood component analysis (NCA) algorithm, the selection of optimal signal measures was performed. Classification using artificial neural networks was performed for three variants: I—open kinetic chain, II—closed kinetic chain, and III—open and closed kinetic chain. Vibroarthrography showed high diagnostic accuracy in determining healthy cartilage from cartilage lesions, and the number of repetitions during examination can be reduced only to closed kinematic chain

    Diagnostics of Articular Cartilage Damage Based on Generated Acoustic Signals Using ANN—Part II: Patellofemoral Joint

    No full text
    Cartilage loss due to osteoarthritis (OA) in the patellofemoral joint provokes pain, stiffness, and restriction of joint motion, which strongly reduces quality of life. Early diagnosis is essential for prolonging painless joint function. Vibroarthrography (VAG) has been proposed in the literature as a safe, noninvasive, and reproducible tool for cartilage evaluation. Until now, however, there have been no strict protocols for VAG acquisition especially in regard to differences between the patellofemoral and tibiofemoral joints. The purpose of this study was to evaluate the proposed examination and acquisition protocol for the patellofemoral joint, as well as to determine the optimal examination protocol to obtain the best diagnostic results. Thirty-four patients scheduled for knee surgery due to cartilage lesions were enrolled in the study and compared with 33 healthy individuals in the control group. VAG acquisition was performed prior to surgery, and cartilage status was evaluated during the surgery as a reference point. Both closed (CKC) and open (OKC) kinetic chains were assessed during VAG. The selection of the optimal signal measures was performed using a neighborhood component analysis (NCA) algorithm. The classification was performed using multilayer perceptron (MLP) and radial basis function (RBF) neural networks. The classification using artificial neural networks was performed for three variants: I. open kinetic chain, II. closed kinetic chain, and III. open and closed kinetic chain. The highest diagnostic accuracy was obtained for variants I and II for the RBF 9-35-2 and MLP 10-16-2 networks, respectively, achieving a classification accuracy of 98.53, a sensitivity of 0.958, and a specificity of 1. For variant III, a diagnostic accuracy of 97.79 was obtained with a sensitivity and specificity of 0.978 for MLP 8-3-2. This indicates a possible simplification of the examination protocol to single kinetic chain analyses
    corecore